Solar Self-Optimization

Solar does the most on the panel it is wired to.

An array makes the most at midday, and most facilities draw the most after it has gone. We set the array against the load every 15 minutes for a year, move the loads that can move into the solar hours, size a battery from what is left, and read the panel again.

DeterminationSpecimen

Self-Consumption Study, Main Service

12 months of interval data and the inverter's record
Exported at noon
92 kW
Used on site
63% of the year
What can move

74 kW of load can run in the solar hours. Moved there, the noon export falls to 6 kW.

Reviewed by an engineer

The Array Against the Load

The meter records what leaves the facility and what comes in, every 15 minutes, and the inverter records what the roof made.

470 kWh exported683 kWh bought backTHE ARRAYTHE LOAD00:0006:0012:0018:0024:00A JUNE WEEKDAY, IN KILOWATTS

Kestrel Park Distribution, the specimen warehouse in the scrolled story, on a June weekday.

Out at midday, back in the evening

An array is sized for the roof. The facility's load follows its own day: a quieter middle, and a busier evening when chargers start, water heaters reheat and the cooling carries the afternoon heat.

So the same meter sends solar out at midday and buys power back after 4 pm, often at a higher rate than the export earns. Both show on the interval record, and neither shows on the bill as a circuit.

The work is done on the panel: find the loads that could run while the sun is up, move them there with fixed rules on a controller, and read the export and the evening import again.

What Decides How Much You Use

When the load runs

Charging, water heating, pre-cooling and process runs that land after sunset and could land before it. Each one moved is solar used on site.

What the roof makes

The array's output through the day and the year, from the inverter's own record, against the facility's load in the same 15 minutes.

What is left over

The export that remains once the loads have moved. That figure, not the array's size, is what a battery is sized from.

What We Answer

How We Do It

  1. MAIN 1200 AScheduleRECRecordercollected afterA month on every boardA year of the utility's own recordImport and export, every 15 minutesThe inverter's log of what the roof made01 Determination

    We read a year of your utility's 15-minute data, import and export, beside the inverter's own record.

  2. 50100150200kW12 am6 am12 pm6 pm12 amA June weekday, the array against the loadEvery 15 minutes, in kWExported, 9 am to 4:15 pm92 kW over the load at noon470 kWhexported in the middle of the day02 Investigation

    We find the hours the array exports and the hours the facility buys back, and read each board for the loads that could move.

  3. 74 kW of load that could run in the sun1Forklift chargers, 36 kW198 kWh a weekday, today 5 pm to 10:30 pm.2Water heaters, 12 kW72 kWh a weekday, today 4 am to 7 am and 4:30 pm to 7:30 pm.3Chilled store, evening run, 10 kW50 kWh a weekday, today 4 pm to 9 pm.4Rooftop units, late afternoon, 16 kW51 kWh a weekday, today 3 pm to 7 pm.Moved, the June weekday exports 128 kWh instead of 470 kWh. A battery is sized on what is left.03 Intervention

    We write the schedules and interlocks that move those loads into the solar hours, and size a battery from what is left.

  4. What you receiveThe year, split four waysMade, used on site, exported and bought back, month by month, against the utility'sown export register.The loads that could moveEach with its kW, its hours today and the hours it could run instead.What is left for a batteryThe export that remains once the loads have moved, in kWh and kW. What each is worthis read off your tariff.A report signed by a licensed engineer under their own licence04 Verification

    We read the export and the evening import again every month, and a licensed engineer signs the result.

Watch the export being read →

What We Measure

12 months of interval data

Your utility's record every 15 minutes, with import and export on separate channels, so the hours the array sends power out are on the record.

The inverter's own record

What the array made in each interval, from the inverter or its portal. Set against the meter, it gives what the facility used of its own solar.

A month on the main boards

Where the two records cannot say which loads draw when, loggers go on the main boards for a month, so each load that could move is read at its circuit.

Loggers are fitted and collected by a licensed electrician with the panel live, and they come off at the end of the window. Nothing is fitted where the utility and the inverter records settle it.

Who Asks for It

  • WarehouseForklifts charging after sunset
  • SchoolEmpty all summer
  • Cold storeCompressors at night
  • GroceryCases through the evening
  • OfficeA roof array, empty weekends
  • ManufacturingA second shift after dark
  • Fleet depotVans charging overnight
  • HotelThe evening peak

What You Receive

  1. The array against the load

    Every 15 minutes for a year: the solar the facility used, the solar it exported, and the hours it bought back.

    From 12 months of interval data
  2. What can move

    The loads that can run in the solar hours, read at their circuits, and the kW each one moves.

    Reviewed by an engineer
  3. The export, read again

    The export and the evening import measured again with the rules running, against the month before.

    Every month the rules run

What It Needs

The work starts from 12 months of your utility's interval data and the inverter's own record. Where the two cannot settle it, loggers go on the main boards for a month.

The rules that move load into the solar hours run on a controller as schedules and interlocks an engineer wrote and signed. It is ours, run by us, and every action it takes can be traced to a rule.

Exporting more solar than you use? Start with the year your meter already has.