on the Loads that Matter.

An Asset Health and Panel Diagnostic is an electrical signature audit: aggregate 3-phase interval data, phase load imbalances, voltage sags, and major motor starting spikes, read from the panel and traced to the loads behind them.

“Compressors and chillers trip breakers and behave erratically, and I need to stop run-to-failure.”

The customer conversation this study answers

Electrical Signature AuditRECORDING
PHASE A · B · CMotor start spike, phase C sagCompressor 2: erratic starts, rising imbalanceFlagged in the Panel Diagnostic Report, before the breaker trips
When You Sell It

Trips, Hot Lugs and Hard Starts
Show Up in the Data First.

Nuisance trips, hot lugs, motors that start hard on humid days: the symptoms show up electrically long before the failure. The audit turns those signatures into a prioritized repair plan.

1

The Erratic Load Call

Breakers trip and reset, compressors short-cycle, nobody can say why. The audit catches the event in the interval data and names the circuit doing it.

2

Before a Maintenance Contract

Baseline every critical load before you price the contract. You quote from measured condition, not guesswork, and the customer sees exactly what they are paying to protect.

3

The Door to Continuous Diagnosis

This audit baselines the panel and onboards it into Wattif AI Fault Diagnosis, so every signature it captured keeps being watched.

What Is in the Report

The Panel Diagnostic Report

A condition report on the panel and every major load on it, page by page: the recorded signals, the findings named by circuit, and a repair plan the customer can act on.

  • Aggregate 3-phase interval data across the recording window, charted per phase.
  • Phase load imbalance, isolated and quantified against accepted limits.
  • RMS voltage sags, when they happen and which starts or faults cause them.
  • Major motor starting spikes, the hard starters and short-cyclers named by circuit.
  • A prioritized repair plan, what to fix now, what to watch, and what is healthy.
  • Your branding throughout, your logo, your company, your customer relationship.
Meyer Electric Co.RPT-2026-0912
Asset Health & Panel Diagnostic

Panel Diagnostic Report

Harbor Cold Storage · MDP · 800A / 480V 3Φ

Loads audited14
Flagged for action3
Cover · Scope and SummaryPage 1 of 4
Section 2 · Recorded Signals

3-Phase Interval Data

Phase C carries the imbalance. The boxed event is a hard motor start with a coincident voltage sag.

Charts · Per-Phase RecordingPage 2 of 4
Section 3 · Findings

Named by Circuit

CircuitFindingStatus
CKT 14Compressor 2Erratic starts, rising imbalanceACT NOW
MDP-BFeeder BVoltage sags on hard startsSCHEDULE
CKT 6Chiller 1Healthy, baselined for watchHEALTHY
Findings · Evidence AttachedPage 3 of 4
Section 4 · Repair Plan

Prioritized, Priced by You

Now: Replace Compressor 2 contactorThis visit
Next: Re-torque Feeder B terminations30 days
Watch: Chiller 1, baselinedFault Watch

Every line becomes a job you quote. The baseline feeds continuous diagnosis.

Plan · Fix, Schedule, WatchPage 4 of 4

Sell the Audit.
Keep the Account.

The audit pays as a project, and the baseline it leaves behind is the start of the monitored contract.